JC75
JC75 JC Type C-Section Truss Component : C-Section & Batten Johor Bahru (JB), Malaysia, Tebrau Manufacturer, Maker, Supplier, Supply | Fort Steel Sdn Bhd
  • The primary building blocks of our truss system is  ¢Ù C-Section ¢Ú Batten .
  • The type of building, roof pitch, roof length, wind load and rain density are some of the deciding factors determining the design of our roof truss system.

D = depth , t = thickness (TCT) , b1 = top flange , b2 = base flange , s = lips

Section Type E D
(mm)
t
(mm)
b1
(mm)
b2
(mm)
s
(mm)
Area
(Ag in mm²)
Weight
(Kg/m)
Ix
(mm⁴)
Iy
(mm⁴)
rx
(cm)
ry
(cm)
Zx
(mmᶟ)
Zy
(mmᶟ)
1 JC75 x 35 x 0.75mm 75 0.75 37.4 35.2 6.4 117.5 0.96 103305 17897 3.013 1.254 2755 734
2 JC75 x 35 x 0.80mm 75 0.80 37.4 35.2 6.4 125.1 1.02 109828 18983 3.010 1.251 2929 779
3 JC75 x 35 x 1.00mm 75 1.00 37.4 35.2 6.4 152.71 1.31 137515 24386 3.001 1.264 3667 1013


Product Tolerances

Fort Steel light weight trusses are produced within the following tolerances :
Length Web (Dim.H) Flange (Dim.B) Thickness
± 5mm ±1mm ± 2mm ± 0.05mm
Longitudinal Tensile Tensile Strength Yield Strength Protective Coating
G550 Min 550 Mpa Min 550 Mpa T-Maz™
Standard Coating Mass Surface Finish Surface Colour  
Y12 Non-spangled Oak  

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version