V-Batten V35
V-Batten V35 Batten Truss Component : C-Section & Batten Johor Bahru (JB), Malaysia, Tebrau Manufacturer, Maker, Supplier, Supply | Fort Steel Sdn Bhd
  • The primary building blocks of our truss system is  ¢Ù C-Section ¢Ú Batten .
  • The type of building, roof pitch, roof length, wind load and rain density are some of the deciding factors determining the design of our roof truss system.

D = depth , t = thickness (TCT) , b1 = top flange , b2 = base flange , s = lips

Section Type D
(mm)
t
(mm)
b1
(mm)
b2
(mm)
s
(mm)
Area
(Ag)
Weight
(kg/m)
Ix
(mm⁴)
Iy
(mm⁴)
rx
(cm)
rx
(cm)
Zx
(mmᶟ)
Zy
(mmᶟ)
1 V35 - 0.45mm 35 0.45 18 50 11 50.40 0.42 9093 9041 1.343 1.339 364 532

 

Product Tolerances

Fort Steel light weight trusses are produced within the following tolerances :

Length Web (Dim.H) Flange (Dim.B) Thickness
± 5mm ±1mm ± 2mm ± 0.05mm
Longitudinal Tensile Tensile Strength Yield Strength Protective Coating
G550 Min 550 Mpa Min 550 Mpa T-Maz™
Standard Coating Mass Surface Finish Surface Colour  
Y12 Non-spangled Oak  